Menu
Product Type
- Gas-Fired(oil-fired) Boilers
- WNS series gas-fired (oil-fired) steam boiler
- WNS series gas-fired (oil-fired) hot water boiler
- SZS series gas-fired (oil-fired) steam boiler
- SZS series gas-fired (oil-fired) hot water boiler
- Coal-Fired Boilers
- DHL series coal-fired steam boiler
- DZL series coal-fired steam boiler
- SZL series coal-fired steam boiler
- DZL series coal-fired hot water boiler
- SZL series coal-fired hot water boiler
- CFB (circulating fluidized bed) coal-fired steam boiler
- CFB(circulating fluidized bed)coal-fired hot water boiler
Complete Project
- 1.5MW gas-fired thermal fluid heater for paper industry
- 4.2MW YLW coal-fired thermal fluid heater for metallurgical industry
- 4 tph WNS series gas-fired fire tube boiler project for NongFu Spring
- 4 tph WNS oil-fired fire tube boiler project for construction industry
- 25 tph SZL series coal-fired water tube boiler project for textile industry
- 10 tph coal-fired water tube boilers for apparel industry
Contact
E-mail Us And Get Price
E-mail: [email protected]
Address:
No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China
Phone:
+86 13506151306
calculation of feed water for 10 ton capacity steam boiler
- E-mail us!If you have any questions!

-
Boiler name: calculation of feed water for 10 ton capacity steam boiler
-
Boiler Distributor:Our product range includes biomass fired thermal fluid heaters, coal fired hot oil boilers, oil/gas fired thermal fluid heaters and molten salt heaters.
-
Available fuel: biomass molding granules, wood chip
-
E-mail: [email protected]
-
Please email or call us for your inquiry
We supply to over 100 countries and regions and have set up offices around the world to ensure prompt delivery of products and services.ZOZEN's main products include industrial boilers, power station boilers, waste heat recovery devices (HRSG), special waste heat boilers, pressure vessels and other five series with more than 400 varieties of specifications, mainly classified as: 10 ~ 220 t/h series power station boilers; SHL series bulk coal-fired Steam and hot water boilers; SZL series pipe assembly boilers; DZL series shell boilers; WNS series, SZS series of oil/gas fired boilers; YLL series of coal-fired thermal fluid heater; YYW series of fuel gas thermal fluid heater; biomass fuel boiler steam and gas combined cycle waste heat boilers, special waste heat boilers and so on.
ZOZEN has built six fully automatic lines for the production of convection pipe, coil pipe, threaded pipe, membrane wall, serpentine tube and header. The parts so produced have consistent dimensions that enable easy assembly and ten years’ extension of a boiler’s life.
If you run into any problems with the boiler, please contact us directly by email or fill out the online service request. We will do our best to resolve any problems you might have within 24 hours.
Steam Calculators: Boiler Calculator
The feedwater flow rate can be calculated from steam mass flow and blowdown rate: Blowdown Mass Flow = Feedwater Mass Flow * Blowdown Rate; Steam Mass Flow = Feedwater Mass Flow - Blowdown Mass Flow; Steam Mass Flow = Feedwater Mass Flow - Feedwater Mass Flow * Blowdown Rate; Feedwater Mass Flow = Steam Mass Flow / [ 1 - Blowdown Rate]
Read MoreSteam Calculators: Boiler Calculator - Energy.gov
Mar 17, 2015· The feedwater flow rate can be calculated from steam mass flow and blowdown rate: Blowdown Mass Flow = Feedwater Mass Flow * Blowdown Rate; Steam Mass Flow = Feedwater Mass Flow - Blowdown Mass Flow; Steam Mass Flow = Feedwater Mass Flow - Feedwater Mass Flow * Blowdown Rate; Feedwater Mass Flow = Steam Mass Flow / [ 1 - Blowdown Rate]
Read MoreProper sizing of Boiler Feedwater System
BHP X 34.5 ÷ 8.337 lbs ÷ 60 min. X 10 = minimum useable capacity in gallons. For example, if you have a 500 HP boiler the calculation will be as follows – 500 x 34.5 ÷ 8.337 ÷ 60 X 10 = 345 gallons
Read MoreBoiler water consumption - Lenntech
Lenntech can provide you all water treatment equipment, including chemicals. Chemicals will condition the water and protect boiler equipment (heater, pump, …). Lenntech can advise you on treatments required on the make-up water, by providing calculations on mass balance in the steam boiler, contributing for lower
Read More16 Steps to Proper Boiler-Feed-Pump Selection | HPAC
Determine the control method to be used. Check the specification.Boiler Ratings - Spirax Sarco | First for Steam Solutions
Equation 3.5.2 can then be used to calculate the steam output: Example 3.5.2 A boiler is rated at 3 000 kW (kJ/s) and operates at 10 bar g with a feedwater temperature of 50°C.
Read MoreSizing a Steam Boiler | U.S. Boiler Company
Dec 05, 2017· Last month we discussed sizing a hot water boiler with a heat loss calculation. Unlike a hot water boiler, a steam boiler is sized by determining the square foot of radiation connected to the steam system. Once that’s been determined, you can accurately select a boiler that’s large enough to heat the connected load (radiation).
Read MoreBoiler Capacity - Engineering ToolBox
Boiler load - the capacity of a steam boiler - is often rated as boiler horse powers, lbs of steam delivered per hour, or BTU. Lbs Steam delivered per Hour. Large boiler capacities are often given in lbs of steam evaporated per hour under specified steam conditions. BTU - British Thermal Units
Read MoreHow to calculate the steam produced (kg) in a boiler - Quora
Jul 25, 2017· Typically boilers of much size would have a steam meter that calculates flow. This is typically a sensor measuring the pressure drop across and orifice. If you don’t have that, then you have two options. Option one is mainly for firetube style boi
Read MoreCalculation Of Water Consumption And Fuel A Boiler
Calculation Of Water Consumption And Fuel A Boiler - posted in Industrial Professionals: Excuse my English. Dear, I am doing my project of memory and partly it must conduct an analysis of the feasibility of putting into operation a boiler, that while I keep the approximate amount of steam that I produce, I could not find a way to estimate consumption water and fuel would be.
Read MoreWhat size boiler do I need? Try our power calculator
System boilers store hot water in a cylinder, so multiple hot taps and showers can be drawn simultaneously. They are sealed units, so need decent mains water pressure to work well. Heat only boilers also store hot water in a cylinder, but the system is …
Read More(PDF) Steam Boiler - ResearchGate
Logically a steam boiler should have a minimum capacity of containing 10 liters of water and its minimum working pressure should be 3.4 Kgf/cm2. No caption available +6
Read MoreSizing boiler feed units vs. condensate return units
Mar 28, 2016· Volume 3/ Issue 1/ March 2016 We’ve previously discussed how to size condensate return units. Sizing a boiler feed unit requires similar information but is affected by differences in design and operation. Condensate return units are generally smaller, fitting their function of collecting steam condensate and pumping it back into the system before too muchRead more
Read MoreBoiler Formulas | Johnston Boiler | Top Quality Boiler
Factor of Evaporation Water enters the boiler at 225°F. The boiler pressure is 100 psi and the boiler water temperature is 338°F. The latent heat is 881 Btu.
Read MoreBoiler Cheat Sheet
feedwater temperature must be taken account of to calculate the real boiler capacity. Thus, in the example above and using an operating pressure of 130 psig (896 kPag) and a water temperature of 180oF (82oC), the real boiler capacity is calculated as follows: ex .: Enthalpy of steam …
Read MoreBlowdown in Boiler | Boiler Blowdown Calculation Formula
Blowdown in Boiler Definition. Blowdown in Boiler, Usually, water which is fed to the boiler contains high Total Dissolved Solids (TDS) content as well as other dissolved and undissolved solids in it. On heating water or converting water to steam, these dissolved solids do not evaporate and gets separated from water or steam and settled at the bottom of the shell.
Read MoreJohnston Boiler Company Boiler Glossary - Steam & Combustion
Nov 03, 2006· Steam Boilers & Appurtenances, Combustion & Instrumentation Controls, Deaerators, Exhaust Systems, Heat Exchangers, Heat Pipes, Industrial Pumps, Water Heaters, Water Softeners, Boiler Seminars, Services & Parts. 8 Common Boiler Formulas BR = (1 / CC) * BC BR = (1 / 8.6) * 10,000 BR = 1,163#/hr Where, BR Blowdown rate BC Boiler capacity in #/hr
Read MoreSteam Calculator: How To Calculate Steam Consumption
Oct 28, 2020· The rate of condensation of steam needs to be taken into account for sizing the steam traps, and also in finalizing the boiler output. What is Warm-Up Load ? During the plant start-up after a long time or from cold, then the steam is required to heat the system uniformly to bring the system close to the normal working temperature of the system.
Read MoreSize Boiler Feed - MathWizard™ - Shipco® Pumps
The receiver size on boiler feed units is typically based on the total system load of all boilers fed by the boiler feed unit with 20 minutes GROSS storage. The size of boiler feed receivers are expressed in gross gallons. Make sure the inlet height is lower or equal to exisiting height on gravity return systems—water does not run uphill!3
Read MoreA steam boiler capacity is 30 tons of steam per hour. Do
Holding capacity will always be lesser than the generating capacity. For example, for 150 ton/hr Bi-Drum oil fired boiler, Total hold up volume is around 61 tons, and Steam drum capacity is merely 13 tons ( But in running condition it will hold ha
Read MoreSIZING FOR CONDENSATE RECEIVERS - PB Heat: Peerless® …
when the boiler feed pump is not operating. Further, the make-up water feeder should be selected with sufficient capacity to take care of the normal firing rate of the boiler. For example, in this case it is desir-able to select a make-up water feeder having a min-imum feeding capacity of 866 lbs. of water per hour. Low Water Cut-Offs on
Read More2. BOILERS - Bureau of Energy Efficiency
2. BOILERS Bureau of Energy Efficiency 27 Syllabus Boilers: Types, Combustion in boilers, Performances evaluation, Analysis of losses, Feed water treatment, Blow down, Energy conservation opportunities. 2.1 Introduction A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam.
Read Morehow to boiler chain grate six ton calculation formula
1 Ton Per Hour Boiler Prices -Boiler Construction Codes. How to Calculate the Fuel Consumption of the Boiler . 2019-4-17 183; Take the 10 ton gas fired boiler for example, we will introduce how to calculate the fuel consumption of the boiler. The 10 ton gas fired boiler has an output of 10 tons per hour, which is also the capacity of the boiler.
Read MoreCalculating Boiler Chemical Requirements – Water
Jun 26, 2017· “H” and “M” values are determined as calcium carbonate from feed water analysis. Example: Field tests on a given feedwater show H = 84 ppm and M = 59 ppm. Non-carbonate hardness (H-M) = 25 ppm as CaCO 3. Assume boiler operates at 10 cycles of concentration, and the residual boiler water alkalinity, M, is 250 ppm.
Read MoreHow to Calculate Operation Cost of Gas Fired Boiler
How to Calculate Operation Cost of Gas Fired Boiler 2018-09-11 10:56:33. Gas fired boiler is one of the most widely used boilers at present. It is a low nitrogen condensing boiler used in many areas, such as residential heating, hotel heating, food factory steam supply and so on.
Read MoreFeed Operations: Steam generation in the feed mill | World
At this point, the pound of water has 180 btus of sensible heat. An additional 970 btus of latent heat must be added to change the water to steam. The addition of the latent heat will change the water to steam, but not raise the temperature. Once the latent heat is added, we have one pound of steam at 0 atmospheric pressure.
Read MoreCalculation for a Boiler Feed Pump - CR4 Discussion Thread
Jun 02, 2017· BOILER FEED WATER PUMP SELECTION: FEED WATER PUMP. Every steam boiler needs one or two feed water pumps. Example: Fire tube steam boiler. Rated pressure 8 bar . Maximum steam production 1000 Kg/h. Piping pressure drop 1,3 bar Pump head 0,5 bar. Pump dimensioning: Head = ( 8+1,3+0,5) + 5% = 10,3 bar (103 m.)
Read More